CODESYS Development System
Compiler Error C0168 Message : 'VAR_CONFIG' declaration only allowed in VAR_CONFIG list Possible error cause : 'VAR_CONFIG' is used outside of a VAR_CONFIG list. Error correction : Use 'VAR_CONFIG' on
CODESYS Development System
Compiler Error C0169 Message : 'VAR_GLOBAL' declaration only allowed in global variable list Possible error cause : 'VAR_GLOBAL' is used outside of global variable lists. Error correction : Use 'VAR_G
CODESYS Development System
Compiler Error C0173 Message : '<keyword>' not allowed in this place Possible error cause : A declaration keyword (example: VAR_INPUT , VAR_OUTPUT , or VAR ) is not allowed at this location. Error cor
CODESYS Development System
Compiler Error C0174 Message : 'VAR_TEMP' declaration not allowed in this place Possible error cause : 'VAR_TEMP' is used outside of a program or function block. Error correction : Use 'VAR_TEMP' insi
CODESYS Development System
Compiler Error C0175 Message : 'RETAIN' or 'PERSISTENT' not allowed in this place Possible error cause : 'RETAIN' or 'PERSISTENT' is used in a function. Error correction : Use 'RETAIN' or 'PERSISTENT'
CODESYS Development System
Compiler Error C0102 Message : Out of retain memory: Variable '<variable name>', <byte size> bytes. Possible error cause : More retain memory is used than is available on the PLC. It is also possible
CODESYS Development System
Compiler Error C0103 Message : Out of retain memory: Variable '<variable name>', <byte size> bytes. (largest contiguous memory gap {2}) Possible error cause : More retain memory is used than is availa
CODESYS Development System
Compiler Error C0104 Message : 'Out of global data memory: Variable '<variable name>', <byte size> bytes. Possible error cause : More memory for data is used than is available on the PLC. It is also p