EtherCAT – PROFIBUS Slave EL6731_0010 Terminal CODESYS supports the EL6731_0010 device from Beckhoff, This device establishes a gateway from EtherCAT to a PROFIBUS Slave. You insert the gateway below
Bus Cycle Task – EtherCAT General Information Generally, for each IEC task, the used input data is read at the start of each task (1) and the written output data is transferred to the I/O driver at th
Command: Scan for Devices Function : The command establishes a temporary connection to the hardware and detects the devices in the network. Then you can apply the scanned devices into the device tree
CODESYS EtherCAT CODESYS GmbH Version: V4.8.0.0, September 2024 www.codesys.com Last update: Tue, 17 Sep 2024 07:34:21 :
CODESYS EtherCAT The integration of the EtherCAT Master in the CODESYS IEC 61131-3 programming system includes the following: Integrated configurator for the master and connected slaves Portable prot
General Tip See the general description for information about the following tabs of the device editor. Tab: <device name> I/O Mapping Tab: <device name> IEC Objects Tab: <device name> Parameters Tab:
Tab: EtherCAT Master – General The tab is used for the configuration of the basic settings for the EtherCAT Master. The basic settings are preset from the device description file. Settings of the conf
Tab: EtherCAT Master – Sync Unit Assignment The tab shows all slaves that are inserted below a specific master with an assignment to the sync units. With the EtherCAT sync units, multiple slaves are c