Performance POUs which use the AXIS_REF_SM3 function block always check whether or not they are called from the bus cycle task. This check can be disabled for time-critical applications by means of th
Tab: Commissioning Caution You can move the drive by means of buttons on this page. The drive may make unexpected movements. Take all necessary safety precautions. This tab is used for testing purpose
Tab: SoftMotion Drive – Position Control On this tab, you set the parameters for the position control. Please also note the example Position Control on the Controller with SM_Drive_PosControl . Table
CODESYS Softmotion Basic :
Overview CODESYS Softmotion Basic provides an interface for function blocks for motion control of individual axes. This interface is based on the PLCopen specification "Function blocks for motion cont
Getting Started with CODESYS Softmotion Basic To program a movement with CODESYS Softmotion Basic , at least one axis needs to be configured in the device tree. This includes setting the axis type ( m
Overview CODESYS SoftMotion distinguishes between movements which only act on a single axis and movements in which two axes are synchronized (for example, via electronic cams or virtual gears). The la
Interruption of Movements Interruption during the deceleration phase Single-axis movements, such as MC_MoveAbsolute , can be interrupted at any time by other movements. This can be a movement to anoth
Synchronous Movements of Two Axes :