AppCallGetProperty2 (FUN) ¶ FUNCTION AppCallGetProperty2 : RTS_IEC_RESULT InOut: Scope Name Type Return AppCallGetProperty2 RTS_IEC_RESULT Input pInstance POINTER TO BYTE ppGetMethod POINTER TO POINTER TO BYTE ppbyValue POINTER TO POINTER TO BYTE ulSize __XWORD
AppCallGetProperty2Release (FUN) ¶ FUNCTION AppCallGetProperty2Release : RTS_IEC_RESULT InOut: Scope Name Type Return AppCallGetProperty2Release RTS_IEC_RESULT Input pbyValue POINTER TO BYTE
AppCallGetProperty3 (FUN) ¶ FUNCTION AppCallGetProperty3 : RTS_IEC_RESULT InOut: Scope Name Type Return AppCallGetProperty3 RTS_IEC_RESULT Input pInstance POINTER TO BYTE ppGetMethod POINTER TO POINTER TO BYTE ppbyValue POINTER TO POINTER TO BYTE ulSize __XWORD ulOffset __XWORD
Operations (GVL) ¶ InOut: Scope Name Type Initial Comment Constant OP_APP_STOP UDINT 1 <category>Operations</category> <description>Operations of the application component. Can be disabled with the event CMPID_CmpMgr::EVT_CmpMgr_DisableOperation!</description> OP_APP_DOWNLOAD UDINT 2 OP_APP_ONLINECHANGE UDINT 3 OP_APP_WRITE_VARIABLES UDINT 4 OP_APP_FORCE_VARIABLES UDINT 5 OP_APP_SET_BREAKPOINT UDINT 6 OP_APP_RESET UDINT 7 OP_APP_START UDINT 8 OP_APP_DELETE_APPLICATION UDINT 9 OP_APP_RESET_ORIGIN UDINT 10
PROJECT_INFO (STRUCT) ¶ TYPE PROJECT_INFO : STRUCT <category>Project information</category> <description> Contains the project information as specified in the project information dialog in CoDeSys. To use this, the checkbox “Automatically generate POUs for property access” in the project information dialog be enabled. </description> <element name=”stProjectName” type=”OUT”>Project name without ending</element> <element name=”stTitle” type=”OUT”>Title</element> <element name=”stVersion” type=”OUT”>Version as string in the format “x.x.x.x”</element> <element name=”stAuthor” type=”OUT”>Author</element> <element name=”stDescription” type=”OUT”>Description</element> InOut: Name Type stProject STRING stTitle STRING stVersion STRING stAuthor STRING stDescription STRING
RESET_OPTION (ENUM) ¶ TYPE RESET_OPTION : <category>Reset option</category> InOut: Name Initial RTS_RESET 0 RTS_RESET_COLD 1 RTS_RESET_ORIGIN 2 RTS_RESET_ORIGIN_DEVICE 3
RetainBackupState (GVL) ¶ InOut: Scope Name Type Initial Comment Constant APP_RBS_UNKNOWN UINT 0 <category>Retain backup state</category> <description> State values for event EVT_RetainBackupState/EVTPARAM_CmpAppRetainBackupState.uiBackupState. </description> <element name=”APP_RBS_UNKNOWN” type=”IN”>Unknown state</element> <element name=”APP_RBS_BACKUP_PREPARE” type=”IN”>Preparation of file backup (gathering information)</element> <element name=”APP_RBS_BACKUP_BEGIN” type=”IN”>File backup begin</element> <element name=”APP_RBS_BACKUP_END” type=”IN”>File backup end</element> <element name=”APP_RBS_RESTORE” type=”IN”>Restore retains from file</element> APP_RBS_BACKUP_PREPARE UINT 1 APP_RBS_BACKUP_BEGIN UINT 2 APP_RBS_BACKUP_END UINT 3 APP_RBS_RESTORE UINT 4
BACnetCommand.InitializeActionCommandBACnetBoolean (METH) ¶ METHOD InitializeActionCommandBACnetBoolean Initialized a BACnet-ActionCommand, which writes a BACnet-Boolean value to another BACnet-Object-Property. The initialized command then normally is used as part of a BACnet-ActionList. InOut: Scope Name Type Comment Input devInst CmpBACnet.IEC_BACNET_DWORD The instance number of the targeted BACnet device. bacObjectInst CmpBACnet.IEC_BACNET_DWORD The instance number of the targeted BACnet object under the BACnet device. bacObjectType CmpBACnet.IEC_BACNET_OBJECT_TYPE The type of the targeted BACnet object under the BACnet device. bacPropertyID CmpBACnet.IEC_BACNET_PROPERTY_ID The property ID of the targetedn property under the BACnet object. priority CmpBACnet.IEC_BACNET_SIGNED The priority used to write the BinaryPV value to the targeted property. postDelay CmpBACnet.IEC_BACNET_UNSIGNED The post delay after writing the BinaryPV value. quitOnFailure CmpBACnet.IEC_BACNET_BOOLEAN Whether the action list execution shall be quited on failure of this action command or not. Inout bacBoolean CmpBACnet.IEC_BACNET_BOOLEAN The boolean value to be written. bacActionCommand CmpBACnet.IEC_BACNET_ACTION_COMMAND The action command structure to be filled.
File and Project Information ¶ Scope Name Type Content FileHeader creationDateTime date 20.04.2021, 15:33:22 companyName string 3S-Smart Software Solutions GmbH libraryFile CmpApp.library primaryProject True productName CODESYS productProfile CODESYS V3.5 SP16 Patch 3 contentFile CmpApp.clean.json version version 2.0.0.0 ProjectInformation LinkInSimulation bool True Released True LastModificationDateTime date 20.04.2021, 15:33:22 LibraryCategories library-category-list System|SysLibs Author string 3S - Smart Software Solutions GmbH Company System CompiledLibraryCompatibilityVersion CODESYS V3.5 SP15 Patch 2 Description See: Description Placeholder CmpApp Project CmpApp Title CmpApp Version version 3.5.17.0
Library Reference ¶ This is a dictionary of all referenced libraries and their name spaces. CmpEventMgr ¶ Library Identification ¶ Placeholder: CmpEventMgr Default Resolution: CmpEventMgr, * (System) Namespace: CmpEventMgr Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpEventMgr SysTypes2 Interfaces ¶ Library Identification ¶ Name: SysTypes2 Interfaces Version: newest Company: System Namespace: SysTypes_Interfaces Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysTypes2 Interfaces, * (System)