SFC Element: Macro Symbol: A macro contains a part of the SFC chart which is not shown in detail in the main view of the editor. Using macros does not influence the processing flow. Macros are used to
Qualifiers for Actions in SFC You assign qualifiers to IEC steps. Qualifiers describe how a step action is processed. Qualifiers are processed by the SFCActionControl function block in the library Iec
SFC flags SFC flags are implicitly generated variables with predefined names. You can use flags to influence the processing of an SFC chart. You can use these flags, for example, to display timeouts o
Library: Analyzation This library contains POUs for the analysis of expressions. When a composite expression has the total value of FALSE , those of its components that contribute to this result can b
Reference: User Interface :
Dialog: Options – SFC editor Symbol: Function : The dialog is used to configure the settings for the SFC editor . Call : Tools → Options command, SFC editor category Tab: Layout Table 5 . Elements Def
Dialog: Settings – SFC Settings Function : The dialog defines the default settings for all POUs which are used in the project and which are programmed in SFC. Call : View → Properties command; context
Command: Add Entry Action Symbol: Function : The command opens the Add Entry Action dialog where you define a new entry action. Depending on the SFC options, a dialog prompt may open for selecting the