INode_TO_IDevice (FUN) ¶ FUNCTION INode_TO_IDevice : IDevice Converts an INode object to an IDevice object. If itfNode is no IDevice object function returns zero. InOut: Scope Name Type Comment Return INode_TO_IDevice IDevice corresponding IDevice or zero if itfNode is no IDevice object Input itfNode INode node to be converted
PropertyConfiguration ¶ ActivatePropertyConfiguration (Method) DeactivatePropertyConfiguration (Method)
INode_TO_IDevice2 (FUN) ¶ FUNCTION INode_TO_IDevice2 : IDevice2 Converts an INode object to an IDevice2 object. If itfNode is no IDevice2 object function returns zero. InOut: Scope Name Type Comment Return INode_TO_IDevice2 IDevice2 corresponding IDevice2 or zero if itfNode is no IDevice2 object Input itfNode INode node to be converted
ILogger.DisableLogger (METH) ¶ METHOD DisableLogger : ERROR Disables logging. InOut: Scope Name Type Return DisableLogger ERROR
ILogger.EnableLogger (METH) ¶ METHOD EnableLogger : ERROR Enables logging. InOut: Scope Name Type Return EnableLogger ERROR Input eMode LOGGER_MODE ctMaxLogMessages CAA.COUNT
ILogger.GetLogEntry (METH) ¶ METHOD GetLogEntry : ERROR Gets the next log entry. InOut: Scope Name Type Comment Return GetLogEntry ERROR Inout LogEntry LOG_ENTRY log entry
INode (ITF) ¶ INTERFACE INode EXTENDS __SYSTEM.IQueryInterface Interface for a node in the device tree. Properties: ChildNodeCount Enable FirstChildNode IsRootNode NextSiblingNode ParentNode SiblingNodeCount Structure: ChildNodeCount (Property) Enable (Property) FirstChildNode (Property) IsRootNode (Property) NextSiblingNode (Property) ParentNode (Property) SiblingNodeCount (Property)
BACnetServer.ConfCOVNotification (METH) ¶ METHOD ConfCOVNotification : CmpBACnet.IEC_BACNET_STATUS Sends a BACnet-ConfCOVNotification-Service for COV-Reporting of a BACnet-Object under the BACnet-Device to another BACnet-Device (target). The results of the service (equalling the answer of the target BACnet-Device) are held in ConfCOVNotificationStatus of this BACnet-Server-FB. Until a answer of the target device is received, the status variable remains in IEC_BACNET_STATUS_BUSY. For more details of the call see documentation of function CmpBACnet.BACnetConfCOVNotification.*) InOut: Scope Name Type Comment Return ConfCOVNotification CmpBACnet.IEC_BACNET_STATUS Input targetDevInst DWORD The target device instance number for the ConfCOVNotification-Service to be issued to. pCOVInfo POINTER TO CmpBACnet.IEC_BACNET_COV_NOTIF_INFO The COV notification info send to the targeted device. pAPDUParams POINTER TO CmpBACnet.IEC_BACNET_APDU_PROPERTIES APDU parameters used for sending the ConfCOVNotification- Service to the targeted device.
INode.ChildNodeCount (PROP) ¶ PROPERTY ChildNodeCount : CAA.Count Returns the number of childs below the current node
INode.Enable (PROP) ¶ PROPERTY Enable : BOOL Set: This property is used for enabling/disabling a node. Note Changes will take effect after reconfiguring (see Reconfigure ). Get: Returns the current value