SMC3_CAN_CMZ_SD_PrepareModeSwitchHoming (FB) ¶ FUNCTION_BLOCK SMC3_CAN_CMZ_SD_PrepareModeSwitchHoming EXTENDS FB_Template_EdgeAbortTimeout InOut: Scope Name Type Comment Inherited from Input xExecute BOOL Rising edge: Starts action. Falling edge: Resets outputs. If a falling edge occurs before the function block has completed its action, the outputs operate in the usual manner and are only reset if either the action is completed or in the event of an error. In this case, the corresponding output values ( xDone , xError , eError ) are present at the outputs for exactly one cycle. FB_Template_Edge Output xDone BOOL TRUE : Action has been successfully completed. FB_Template_Edge xBusy BOOL TRUE : Function block in operation. FB_Template_Edge xError BOOL TRUE : Error has occurred. Function block aborts action. FALSE : No error FB_Template_Edge eError WORD Local library error ID FB_Template_Edge Input xAbort BOOL TRUE : The action is stopped immediately and all outputs are reset to their initial values. FB_Template_EdgeAbort udiTimeOut UDINT The time (µs) after which an FB (e.g. requiring an external acknowledgement) aborts operation due to a timeout with error message. FB_Template_EdgeAbortTimeout pAxis POINTER TO AXIS_REF_CAN_CMZ_SD Methods: prv_Abort prv_CyclicAction prv_Start Structure: prv_Abort (Method) prv_CyclicAction (Method) prv_Start (Method)
SMC3_CAN_CMZ_SD_PrepareModeSwitchHoming.prv_Abort (METH) ¶ METHOD prv_Abort : BOOL InOut: Scope Name Type Return prv_Abort BOOL
SMC3_CAN_CMZ_SD_PrepareModeSwitchHoming.prv_CyclicAction (METH) ¶ METHOD prv_CyclicAction : BOOL InOut: Scope Name Type Return prv_CyclicAction BOOL
SMC3_CAN_CMZ_SD_PrepareModeSwitchHoming.prv_Start (METH) ¶ METHOD prv_Start : BOOL InOut: Scope Name Type Return prv_Start BOOL
ParameterAccess ¶ ConvertReceivedDriveParameter (Method) ConvertTransmitDriveParameter (Method) GetMappedDriveParameter (Method) GetParamDirectValue (Method) SetParamDirectValue (Method)
AXIS_REF_CAN_DS402_CS.ConvertReceivedDriveParameter (METH) ¶ METHOD ConvertReceivedDriveParameter : BOOL InOut: Scope Name Type Input diParameterNumber DINT pdwValue POINTER TO DWORD usiBitLength USINT Return ConvertReceivedDriveParameter BOOL Output fValue LREAL bUseDword BOOL
AXIS_REF_CAN_DS402_CS.ConvertTransmitDriveParameter (METH) ¶ METHOD ConvertTransmitDriveParameter : BOOL InOut: Scope Name Type Input diParameterNumber DINT fValue LREAL bUseDword BOOL pdwValue POINTER TO DWORD Return ConvertTransmitDriveParameter BOOL
AXIS_REF_CAN_DS402_CS.GetMappedDriveParameter (METH) ¶ METHOD GetMappedDriveParameter : BOOL InOut: Scope Name Type Input bRead BOOL diParameterNumber DINT Return GetMappedDriveParameter BOOL Output diDriveParameterNumber DINT usiDataLength USINT
AXIS_REF_CAN_DS402_CS.GetParamDirectValue (METH) ¶ METHOD GetParamDirectValue : BOOL InOut: Scope Name Type Input diParameterNumber DINT Return GetParamDirectValue BOOL Output dwValue DWORD fValue LREAL bUseDword BOOL
AXIS_REF_CAN_DS402_CS.SetParamDirectValue (METH) ¶ METHOD SetParamDirectValue : BOOL InOut: Scope Name Type Input diParameterNumber DINT dwValue DWORD fValue LREAL bUseDword BOOL Return SetParamDirectValue BOOL