IecVarAccess.VarAccGetUANodeClass (METH) ¶ METHOD VarAccGetUANodeClass : RTS_IEC_RESULT InOut: Scope Name Type Return VarAccGetUANodeClass RTS_IEC_RESULT Input hNode RTS_IEC_HANDLE pVarInfo POINTER TO VariableInformationStruct2 Output nodeClass OpcUa_NodeClass
IecVarAccess.VarAccGetUAParentReferenceType (METH) ¶ METHOD VarAccGetUAParentReferenceType : RTS_IEC_RESULT InOut: Scope Name Type Return VarAccGetUAParentReferenceType RTS_IEC_RESULT Input hNode RTS_IEC_HANDLE pVarInfo POINTER TO VariableInformationStruct2 Output pReferenceType POINTER TO OpcUa_NodeId
IecVarAccess.VarAccGetUATypeDefinition (METH) ¶ METHOD VarAccGetUATypeDefinition : RTS_IEC_RESULT InOut: Scope Name Type Return VarAccGetUATypeDefinition RTS_IEC_RESULT Input hNode RTS_IEC_HANDLE pVarInfo POINTER TO VariableInformationStruct2 Output pTypeDefinition POINTER TO OpcUa_NodeId
IecVarAccess11 ¶ VarAccExecuteCall (Method) VarAccGetEnumMemberAttributeList (Method) VarAccGetNumOfTypeAttributes (Method) VarAccGetTypeAttributeByIndex (Method)
IecVarAccess.VarAccExecuteCall (METH) ¶ METHOD VarAccExecuteCall : RTS_IEC_RESULT InOut: Scope Name Type Comment Return VarAccExecuteCall RTS_IEC_RESULT Input pNode IBaseTreeNode pVariableInformation POINTER TO VariableInformationStruct pArgumentBuffer POINTER TO BYTE buffer where the struct with the arguments is located. nArgumentBufferSize XWORD size of the argument buffer
IecVarAccess.VarAccHasBaseType (METH) ¶ METHOD VarAccHasBaseType : BOOL Returns true if the type has a base type. InOut: Scope Name Type Return VarAccHasBaseType BOOL Input typeDesc ITypeDesc
IIecVarAccess9 ¶ VarAccBrowseDown2 (Method) VarAccBrowseGetNext2 (Method) VarAccBrowseRecursive (Method) VarAccBrowseUp2 (Method) VarAccExitVarInfo (Method) VarAccGetClientOffset (Method) VarAccGetNode4 (Method) VarAccGetNodeFullPath4 (Method) VarAccGetNodeName4 (Method) VarAccInitVarInfo (Method)
InformationModelMetaData ¶ VarAccGetUAEntryPoints (Method) VarAccGetUAInformationModel (Method) VarAccGetUANamespace (Method)
IoConfigParameterIDs (GVL) ¶ InOut: Scope Name Type Initial Comment Constant PN_CFG_NUM_OF_INPUTS UDINT 16#0 PN_CFG_NUM_OF_OUTPUTS UDINT 16#10000 PNM_MODULE_PARAM_OFFSET UDINT 512 PNM_MODULE_PARAM_ID UDINT 513 PN_PRM_VENDOR_ID UDINT 1 PN_PRM_DEVICE_ID UDINT 2 PN_PRM_REVISION_ID UDINT 3 PN_PRM_IDENTIFY_ONOFF UDINT 7 PN_PRM_STATION_NAME UDINT 10 PN_PRM_MAC_ADDRESS UDINT 11 PN_PRM_IP_ADDRESS UDINT 12 PN_PRM_NETMASK UDINT 13 PN_PRM_MODULEIDENTNUMBER UDINT 14 PN_PRM_STATION_TYPE UDINT 16 15 Identdata
PNConfigParameters (PARAMS) ¶ InOut: Scope Name Type Initial Comment Constant PNM_MAX_ALARMS UINT 32 max. number of alarms stored internally PNM_MAX_CONFIGURED_DEVICES UINT 256 max. numbers of devices in configuration (enabled and disabled)