DCP_GetOptions (STRUCT) ¶ TYPE DCP_GetOptions : STRUCT DCP-Options that can be read out by DCP_Get or that are reported by DCP_Identify InOut: Name Type MAC BIT StationName BIT IPSettings BIT DeviceID BIT DeviceRole BIT TypeOfStation BIT DeviceInstance BIT
Help ¶ CompareMAC (Method) LogErrorTxt (Method) LogHeaderLine (Method) LogInfo (Method)
DCP_ResetMode (ENUM) ¶ TYPE DCP_ResetMode : The DCP-Reset Mode defines which data is cleared from the device. Attributes: qualified_only InOut: Name Initial Comment FactoryReset 0 Default, reset all stored data ResetApplicationData 1 Reset data which have been stored permanent in submodules and modules to factory values (e.g. I&M1-3). ResetCommunicationParameter 2 All parameters active for the interface or the ports and the ARs shall be set to the default values and if permanently stored reset (e.g. Stationname, IP-Suite, Port-Data) ResetEngineeringParameter 3 Reset engineering parameters, e.g. an application program or configuration loaded by an engineering system shall be reset ResetAllStoredData 4 ResetApplicationData + ResetCommunicationParameter + ResetEngineeringParameter ResetDevice 8 Same as ResetAllStoredData applied to ALL interfaces ResetAndRestoreData 9 Reset installed software revisions to factory images.
IoDrvCIFXProfiNet.TryGetAddress (METH) ¶ METHOD TryGetAddress : BOOL InOut: Scope Name Type Comment Return TryGetAddress BOOL Input ID DWORD Slot or subslot handle Inout ADDR CommFB.ADDR_TYPE Physical address information Output STATUS DWORD Last detected status
ChannelProperties_Type (ENUM) ¶ TYPE ChannelProperties_Type : Attributes: qualified_only InOut: Name Initial Comment Unspecified 0 Shall be used if the field ChannelNumber contains the value 0x8000 (submodule) Furthermore, it shall be used if none of the below defined types are appropriate. BitSize1 1 BitSize2 2 BitSize4 3 BitSize8 4 BitSize16 5 BitSize32 6 BitSize64 7
IoDrvCIFXProfiNet.ConfigureFirmware (METH) ¶ METHOD ConfigureFirmware : UDINT InOut: Scope Name Type Return ConfigureFirmware UDINT Input pConnector POINTER TO IoCOnfigConnector
IoDrvCIFXProfiNet.ConfigureWatchdog (METH) ¶ METHOD ConfigureWatchdog : UDINT InOut: Scope Name Type Return ConfigureWatchdog UDINT Input pConnector POINTER TO IoConfigConnector
DiagnosisDirection (ENUM) ¶ TYPE DiagnosisDirection : The direction of the IO-data that is affected by a diagnosis Attributes: qualified_only InOut: Name Comment Undefined (data is not init.) In Input data Out Output data InOut Input/Output data ManufacturerSpecific manufacturer specific (might be used for both directions)
IOL_AdSS_TeachFunction (ENUM) ¶ TYPE IOL_AdSS_TeachFunction : Attributes: qualified_only InOut: Name Initial Comment no_teach 0 no function selected teach_1 1 start teach step 1 functionality teach_2 2 start teach step 2 functionality apply 3 apply two value teach results abort 4 abort actual teach sequence
IOL_AdSS_TeachMode (ENUM) ¶ TYPE IOL_AdSS_TeachMode : Attributes: qualified_only InOut: Name Initial Comment no_teach 0 no teach-in action single_value 1 single value teach-in two_value 2 two value teach-in dynamic 3 dynamic teach-in