Library Reference ¶ This is a dictionary of all referenced libraries and their name spaces. 3SLicense ¶ Library Identification ¶ Placeholder: 3SLicense Default Resolution: 3SLicense, * (3S - Smart Software Solutions GmbH) Namespace: _3S_LICENSE Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: 3SLicense Base Interfaces ¶ Library Identification ¶ Name: Base Interfaces Version: newest Company: System Namespace: IBaseLibrary Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: Base Interfaces, * (System) CAA Device Diagnosis ¶ Library Identification ¶ Placeholder: CAA Device Diagnosis Default Resolution: CAA Device Diagnosis, * (CAA Technical Workgroup) Namespace: DED Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CAA Device Diagnosis CAA Types Extern ¶ Library Identification ¶ Placeholder: CAA Types Default Resolution: CAA Types Extern, * (CAA Technical Workgroup) Namespace: CAA Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: True SystemLibrary: False Key: CAA Types CmpApp ¶ Library Identification ¶ Placeholder: CmpApp Default Resolution: CmpApp, * (System) Namespace: CmpApp Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpApp CmpBinTagUtilIec ¶ Library Identification ¶ Placeholder: CmpBinTagUtilIec Default Resolution: CmpBinTagUtilIec, * (System) Namespace: CmpBinTagUtilIec Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpBinTagUtilIec CmpErrors2 Interfaces ¶ Library Identification ¶ Name: CmpErrors2 Interfaces Version: newest Company: System Namespace: CmpErrors Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpErrors2 Interfaces, * (System) CmpLog ¶ Library Identification ¶ Placeholder: CmpLog Default Resolution: CmpLog, * (System) Namespace: CmpLog Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpLog CmpSchedule ¶ Library Identification ¶ Placeholder: CmpSchedule Default Resolution: CmpSchedule, * (System) Namespace: CmpSchedule Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpSchedule CmpSrv ¶ Library Identification ¶ Placeholder: CmpSrv Default Resolution: CmpSrv, * (System) Namespace: CmpSrv Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: CmpSrv CommFB ¶ Library Identification ¶ Placeholder: CommFB Default Resolution: CommFB, * (3S - Smart Software Solutions GmbH) Namespace: CommFB Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: True SystemLibrary: False Key: CommFB Component Manager ¶ Library Identification ¶ Placeholder: Component Manager Default Resolution: Component Manager, * (System) Namespace: Component_Manager Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: Component Manager IODrvEtherCAT ¶ Library Identification ¶ Placeholder: IODrvEtherCAT Default Resolution: IODrvEtherCAT, * (3S - Smart Software Solutions GmbH) Namespace: IoDrvEthercatLib Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IODrvEtherCAT Library Parameter ¶ Parameter: ETC_MAX_SLAVES = 1024 Parameter: MAX_ASYNC_MSG = 4 Parameter: MAX_MAILBOX_CHANNELS = 100 Parameter: MAX_SDO_CHANNELS = 100 IoDriver Parameter2 Interfaces ¶ Library Identification ¶ Name: IoDriver Parameter2 Interfaces Version: newest Company: System Namespace: IIoDrvParameter Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IoDriver Parameter2 Interfaces, * (System) IoDriver ProfiNet2 Interfaces ¶ Library Identification ¶ Name: IoDriver ProfiNet2 Interfaces Version: newest Company: System Namespace: IIoDrvProfiNet Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IoDriver ProfiNet2 Interfaces, * (System) IoDriver2 Interfaces ¶ Library Identification ¶ Name: IoDriver2 Interfaces Version: newest Company: System Namespace: IIoDrv Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IoDriver2 Interfaces, * (System) IoDrvBase ¶ Library Identification ¶ Placeholder: IoDrvBase Default Resolution: IoDrvBase, * (System) Namespace: IoDrvBase Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IoDrvBase IoStandard ¶ Library Identification ¶ Placeholder: IoStandard Default Resolution: IoStandard, * (System) Namespace: IoStandard Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: IoStandard Rts Service Handler ¶ Library Identification ¶ Placeholder: Rts Service Handler Default Resolution: Rts Service Handler, * (3S - Smart Software Solutions GmbH) Namespace: GSH Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: Rts Service Handler Standard ¶ Library Identification ¶ Placeholder: Standard Default Resolution: Standard, * (System) Namespace: Standard Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: Standard SysCpuHandling ¶ Library Identification ¶ Placeholder: SysCpuHandling Default Resolution: SysCpuHandling, * (System) Namespace: SysCpuHandling Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysCpuHandling SysMem ¶ Library Identification ¶ Placeholder: SysMem Default Resolution: SysMem, * (System) Namespace: SysMem Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysMem SysTarget ¶ Library Identification ¶ Placeholder: SysTarget Default Resolution: SysTarget, * (System) Namespace: SysTarget Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysTarget SysTime ¶ Library Identification ¶ Name: SysTime Version: 3.5.17.0 Company: System Namespace: SysTime Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysTime, 3.5.17.0 (System) SysTypes2 Interfaces ¶ Library Identification ¶ Name: SysTypes2 Interfaces Version: newest Company: System Namespace: SysTypes Library Properties ¶ LinkAllContent: False Optional: False QualifiedOnly: False SystemLibrary: False Key: SysTypes2 Interfaces, * (System)
IoDrvEL6631Diag.Enable (PROP) ¶ PROPERTY Enable : BOOL This property returns if the node is enabled in the device tree. The setter can be used to change the Enabled flag. If enabling/disabling is not supported on the node the flag’s value will not change.
IoDrvEL6631Diag.FirstChildNode (PROP) ¶ PROPERTY FirstChildNode : DED.INode
IoDrvEL6631Diag.Index (PROP) ¶ PROPERTY Index : UDINT
IoDrvEL6631Diag.IsRootNode (PROP) ¶ PROPERTY IsRootNode : BOOL
IoDrvEL6631Diag.NextSiblingNode (PROP) ¶ PROPERTY NextSiblingNode : DED.INode
IoDrvEL6631Diag.ParentNode (PROP) ¶ PROPERTY ParentNode : DED.INode
IoDrvEL6631Diag.SiblingNodeCount (PROP) ¶ PROPERTY SiblingNodeCount : CAA.Count
IoDrvEL6631Diag.SetCommunicationState (METH) ¶ METHOD SetCommunicationState : DED.ERROR InOut: Scope Name Type Return SetCommunicationState DED.ERROR Input eRequestedState DED.DEVICE_TRANSITION_STATE
PNSlave (FB) ¶ FUNCTION_BLOCK PNSlave InOut: Scope Name Type Comment Output xRunning BOOL PNIOStatus = 0 xBusy BOOL PNIOStatus = 1 xError BOOL PNIOStatus > 1 PNIOStatus UINT returns value of 0xann0:1 PnIoBoxState.pniostate 0 = No error 1 = ProfinetDevice state machine is in boot mode 2 = Device not found 3 = The stationname is not unique 4 = IP could not set 5 = IP conflict 6 = DCP set was not successful 7 = Watchdog error 8 = Datahold error 9 = RTC3: Sync signal could not started 10 = Profinet controller has a link error 11 = The aliasname is not unique 12 = The automatic name assignement isn’t possible - wrong device type 13 = IOC-AR is established but no application ready 14 = IOC-AR is established but module difference 15 = At least one InputCR is invalid, provider in stop or problemindicator is set 16 = At least one OutputCR is invalid, provider in stop or problemindicator is set 31 = only for EtherCAT gateways: WC-State of cyclic EtherCAT frame is 1 Properties: ID Methods: GetID Structure: CommFB GetID (Method) ID (Property)