Functions CANopen Safety CANopen Safety is released as a European standard (EN 50325-5). This means that data can be transmitted via CAN networks which meet the requirements for SIL3 applications. Thi
CANopen Diagnosis The chapter describes the diagnosis options offered by the CANopen protocol. CANopen State A CANopen network consists of a NMT master (network management) and NMT slaves. In this cas
Diagnosis in the Application CANopen State The CANopen state of a device can be interrogated in the application in three different ways: GET_STATE function block ( CAA CiA 405 library) <name in device
Diagnosis in the User Interface CANopen Manager (Master) device tree In online mode, the device tree allows for a pinpointing of a pending diagnosis. Green symbol when the device is OPERATIONAL. Error
Troubleshooting Table 16 . CANopen Manager (Master) Problem Possible Solution The CAN bus node is red or has a red exclamation mark. See the general troubleshooting for the CAN bus. The CANopen Manage
Libraries: CANopen Manager (Master) CAA CiA 405 3S CANopenStack 3S CANopen Safety :
CANopen Local Device (Slave) :
General In CODESYS , a CANopen Local Device is a slave device that you insert in the device tree of a project directly below a CAN bus node. As a result, the CODESYS runtime acts as a CANopen Slave. (
Configuration Tip See the general description for information about the following tabs of the device editor. Tab: <device name> I/O Mapping Tab: <device name> IEC Objects Tab: <device name> Parameters