CODESYS Safety for EtherCAT Safety Module
FB_MON Description Function Block The FB_MON function block can be used, for example, to implement a safety door circuit with up to four ( bMonIn(x) ) inputs. Using the Negation command, each of the f
CODESYS Safety for EtherCAT Safety Module
FB_MUTING Description Function Block The FB_MUTING function block implements an intended suppression of the safety function, for example to transport material into the safety area. The output of the f
CODESYS Safety for EtherCAT Safety Module
FB_MODE Description Function Block The FB_MODE function block can be used to implement operating mode selector switches. The function block has 8 inputs and 8 outputs which are looped through one-to-o
CODESYS Safety for EtherCAT Safety Module
FB_OR Description Function Block Using the FB_OR function block, several input signals can be linked via OR to make an output signal. In addition, each input can have a setting as to whether or not it
CODESYS Safety for EtherCAT Safety Module
FB_RS Description Function Block The FB_RS function block implements a Reset/Set functionality. A logic 1 at the bSafeSet input and a logic 0 at the bSafeReset input results in a logic 1 at the output
CODESYS Safety for EtherCAT Safety Module
FB_SR Description Function Block The FB_SR function block implements a Set/Reset functionality. A logic 1 at the bSafeSet input and a logic 0 at the bSafeReset input results in a logic 1 at the output
CODESYS Safety for EtherCAT Safety Module
FB_TOF Description Function Block The FB_TOF function block is used to implement a switch-off delay. A logic 1 at the bTofIn input is extended by the set time forwarded to the output. If the input is
CODESYS Safety for EtherCAT Safety Module
FB_TON Description Function Block The FB_TON function block is used to implement a switch-on delay. A logic 1 at the bTonIn input is extended by the set time forwarded to the output. If the input is s
CODESYS Safety for EtherCAT Safety Module
FB_TWOHAND Description Function Block The FB_TWOHAND function block implements a two-hand circuit in which both input groups must be actuated at the same time in order to switch the output. The output
CODESYS Safety for EtherCAT Safety Module
Library: TcEL69xxAnalogFBs :